Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Chinese Journal of Gastrointestinal Surgery ; (12): 628-631, 2013.
Article in Chinese | WPRIM | ID: wpr-357174

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the clinical effectiveness of three localization methods, including methylene blue, metal clips and intraoperative colonoscopy in laparoscopic colorectal surgery.</p><p><b>METHODS</b>A retrospective analysis was performed to review the clinical data of 64 patients who underwent the laparoscopic colorectal operations in Cancer Hospital of Fudan University from December 2009 to June 2012. Three methods of tumor localization were used perioperatively, including 23 cases of methylene blue, 20 of metal clips and 21 of colonoscopy.</p><p><b>RESULTS</b>Operations were successfully performed in this cohort and there were no deaths or complications. In methylene blue group, intraoperative colonoscopy was performed in two cases because of the inability to visualize blue dye on the serosal surface of the intestinal wall, another 2 cases were converted to open operation because of methylene blue diffusion and inability to identify resection margin. Intraoperative colonoscopic localization was required for 3 cases of sigmoid colon or upper rectal tumor because of inaccurate tumor localization by metal clips. Poor operative exposure due to obvious bowel distension prompted the conversion to open surgery in 2 cases of colonoscopy localization group, and the accurate position of the lesion was not found in another 2 cases due to long pedunculated adenoma.</p><p><b>CONCLUSIONS</b>Colorectal tumor can be localized effectively by endoscopic methylene blue tattooing at a maximum of 2 tumors before operation and the method of 4-point positioning can significantly improve the accuracy of colorectal tumor localization. Tumor localization preoperatively on the day of surgery by metal clip is accurate for the right or left colon cancer. Intraoperative colonoscopy can localize tumor accurately and rapidly for rectosigmoid or descending tumor, and the incidence of bowel distension can be significantly reduced. Localization method should be considered according to the tumor location and surgical procedure.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Colorectal Neoplasms , General Surgery , Laparoscopy , Methods , Retrospective Studies , Treatment Outcome
2.
Chinese Journal of Gastrointestinal Surgery ; (12): 330-332, 2011.
Article in Chinese | WPRIM | ID: wpr-237123

ABSTRACT

<p><b>OBJECTIVE</b>To prospectively evaluate the safety and efficacy of nickel- titanium temperature-dependent memory-shape device(CAR27) for colorectal anastomosis.</p><p><b>METHODS</b>Sixty colorectal cancer patients were randomly divided into two groups and received colorectal anastomosis with CAR27 or traditional stapling device. Complications, bowel function return, and the extrusion of anastomosis ring were prospectively monitored.</p><p><b>RESULTS</b>Both CAR27 and stapler group had one case of anastomotic leakage. Other complications such as stricture or obstruction were not found. Time for anastomosis of the two groups were (10.1±1.2) minutes and (11.2±2.1) minutes respectively. Time to first flatus was(3.2±1.2) days and (3.5±1.4) days respectively. Time to food intake resumption was (4.0±1.4) days and (4.3±1.3) days respectively. The differences above between the two groups were not statistically significant(P>0.05). The ring was expelled with stool within 7-16 days. The two groups were similar in operative time and the return of bowel function.</p><p><b>CONCLUSION</b>CAR27 is safe and simple for colorectal anastomosis.</p>


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Anastomosis, Surgical , Colorectal Neoplasms , General Surgery , Colorectal Surgery , Nickel , Prospective Studies , Titanium
3.
Chinese Journal of Surgery ; (12): 1638-1641, 2008.
Article in Chinese | WPRIM | ID: wpr-275962

ABSTRACT

<p><b>OBJECTIVE</b>To assess short to midterm outcome of endovascular aneurysm repair (EVAR) of infrarenal abdominal aortic aneurysms (AAA) in 105 cases.</p><p><b>METHODS</b>Stent-grafts were placed into 105 patients with infrarenal AAA between January 2001 and February 2007. The clinical data of those cases were retrospectively analyzed.</p><p><b>RESULTS</b>Primary technical success rate was 100%. Eighty-two cases (78.09%) were followed-up for 1 to 73 months (mean, 8.9 +/- 5.8 months). Three cases (2.86%) died during peri-operative period, from acute cardiac infarction, multi-organ failure and significant upper gastrointestinal bleeding, respectively. Another one died from hepatic cancer 30 months after EVAR. Twenty-one cases experienced primary endoleak. Eighteen were type I, among which 10 underwent secondary intervention in the form of balloon dilatation (n = 9) and stent-graft placement (n = 1), 8 sealed spontaneously. Two cases were type II and sealed spontaneously. One type III was treated by placing a stent-graft. An emergent femorofemoral crossover was performed for one graft limb thrombosis 2 weeks after EVAR. Four late type I endoleaks occurred. One stent-graft migration without endoleak was cured conservatively. Two stent-graft infections occurred 1 month and 3 months after EVAR respectively, and were cured with debridement, drainage and antibiotics. Nine femorofemoral or iliofemoral bypass and three internal iliac bypasses were all patent during the follow-up period.</p><p><b>CONCLUSION</b>Endovascular repair is a safe and effective method for infrarenal AAA with perfect short to midterm outcomes.</p>


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Angioplasty, Balloon , Aortic Aneurysm, Abdominal , General Surgery , Blood Vessel Prosthesis Implantation , Methods , Follow-Up Studies , Postoperative Complications , Retrospective Studies , Stents , Treatment Outcome
4.
Chinese Journal of Surgery ; (12): 1600-1603, 2007.
Article in Chinese | WPRIM | ID: wpr-338104

ABSTRACT

<p><b>OBJECTIVE</b>To report an initial experience with the endovascular repair of descending thoracic aortic aneurysm (DTAA).</p><p><b>METHODS</b>Endoprostheses were placed into 41 patients with DTAA between January 2001 and July 2007 which were retrospectively analyzed. The preliminary right-left carotid and left carotid-subclavian bypass was performed in 4 cases in which the distances from the proximal aneurysm to the origin of the left common carotid artery were no longer than 15 mm. EVAR was conducted 1 week after the bypass or immediately.</p><p><b>RESULTS</b>All stent grafts were deployed in proper position. There were two deaths (4.9%) during perioperative period, resulting from multiorgan failure and acute cardiac infarction, respectively. Eighteen endoleaks occurred immediately after EVAR (43.9%), four disappeared after balloon dilatation. There were two acute renal insufficiencies (4.9%), one requiring hemodialysis for more than 30 days. Follow-up, which ranged from 1 to 60 months [median, (18.6 +/- 4.2) months] was carried out in 26 patients (63.4%). Type-I endoleak and type-III endoleak were detected in two patients in 4 years and 2 years after EVAR, might because of migration, and were corrected using another stent-graft each. Two patients died of other diseases during follow-up. Complete thrombosis of the thoracic aneurysm sac with no late migration or endoleaks was revealed on CT at 3 months postoperatively in the remaining patients. The decrease in maximal aneurysm diameter was 0-22 mm [median, (8.3 +/- 4.5) mm] and the prosthetic vascular grafts in four patients with preliminary carotid subclavian bypass surgery were patent during the follow-up period.</p><p><b>CONCLUSIONS</b>The treatment of descending thoracic aortic aneurysm with an endovascular approach is feasible with less trauma, quick recovery and less complications. It may offer the best means of therapy for high risk patients.</p>


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Thoracic , General Surgery , Blood Vessel Prosthesis Implantation , Methods , Follow-Up Studies , Postoperative Complications , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL